PREVALENCE OF GASTRO-INTESTINAL AND ECTO PARASITES OF GOATS AND SHEEP IN MAKURDI METROPOLIS

This research work is limited to Makurdi (Wadata and North bank) in Benue State. All the sheep and goats from different origins, in different age group and sex brought to slaughter house at the time of visit were targeted as study population, a simple random sampling method was employed in selecting 50 goats and 50 sheep, making a total of 100 samples. Standard laboratory parasitological techniques was used in this study including Simple test tube flotation, sedimentation technique, McMaster faecal egg count. Prevalence of endo and ectoparasitic infestation was significantly higher among Makurdi indigenous sheep and goats. The parasite include Amblyomma spp (male hard tick), Dermacenter spp (male hard tick), Dematopinus (biting lice), Hematopinus (sucking lice). Many factors may be responsible for this. It is revealed that most of the animals examined during the present survey had low to moderate parasitic infestation, suggesting that the infections were usually sub-clinical. It was recommended that appropriate gastrointestinal parasites (GIT) parasite control strategy is needed which should be based on cost effective studies to optimize production and more attention should be paid to sheep and goat internal and external parasites, epidemiology and control nation-wide.
Read More

REDESIGN OF A MULTIPLE HEAT TRANSFER MODE CHARCOAL OVEN

This project concerns the unifying the temperature of the baking chambers of the oven using a regulating surface to regulate the mass flow rate of the converted heat from the first shelf to the second shelf experimentally, the dimension of the oven was 76.2cm x 35.6cm x 40.6cm. The result shows that at a certain reduction percentage of the area of the regulating plate and the temperature at the both portion will be uniform. The use of aluminum plate to increase rate of heat supplied to the baking chamber as result its high conductivity and the attempt to reduce losses in the baking chamber by using the aluminum foil and the iron wood insulation
Read More

EVALUTION OF THE ENVIRONMENTAL RADIOACTIVITY AROUND DANGOTE CEMENT ESCAVATION SITE

The aim of this research work is to measure and analyse the environmental radioactivity around Dangote cement, excavation site. To obtain data that will serve as reference material for environment assessment. The method of radiation measurement employed in this work, was direct observation and measurement of radiation from the excavation site using the radiation detectors. These detectors were held one meter above the radioactive sources at various distances of the mining excavation site of Dangote Cement Factory, Gboko. Finally, the background count was taken 200 meters from the excavation site. Readings were taken from two points 300 meters away from each other named excavation point A and B and 3 sets of readings each was taken at each point of measurement for every two minutes The direct observation and measurement of radiation from the excavation site using the radiation detector was obtained at significant values and the difference between them were almost the same. At point A, from table 4.1 the result shows the various average dose rates at various time intervals, with an insignificant average dose of 0.0333±0.0133(mSv/yr). From table 4.2, it shows an insignificant level of average exposure of 0.176±0.015(mR/hr). From table 4.3, the average activity shows an insignificant average activity of 3.46±0.19(KBq). From table 4.4, shows the average dose at point B, with an insignificant average of 0.352±0.434(mSv/yr). From table 4.5, it shows the average exposure an insignificant total average of 0.2668±0.078(mR/hr). From table 4.6, it shows average activity with an insignificant total average of 3.06±0.300(KBq). Therefore, this indicates that the result from the radiation excavates obtained was insignificant at a significance level of 1mSv/yr as recommended by the ICRP. The level of activities carried out by the people around the site must be reduced, because continuous accumulation of radiation may still result to health hazard. It is therefore recommended that there should be occupational and public awareness on the presence of natural radiation especially of limestone mining and cement production in the environment and their possible health hazards, background radiation and proper health monitoring should also be part of environmental assessment for industrial and mining project
Read More

EFFECT OF RADIOCLIMATIC VARIABLES ON RADIO SIGNAL PROPAGATION AT SOKOTO, NIGERIA

The aim of this study was to determine the effect of radioclimatic variables on radio signal propagation at Sokoto, Nigeria. The statistical analysis for the 5 years (2006 – 2010) data has been carried out and the result has shown how these meteorological parameters vary within the study period in Sokoto. The effects of radioclimatic variables on signal propagation in Sokoto, Nigeria has been investigated. The results show that there is an increase in the values of the effective earth radius (k-factor) and radio refractive index (n) in the region. It was also observed that there was a significant increase in the atmospheric temperature during the dry season and as well an increase in the months of the rainy season due to the rise in the atmospheric moisture content in the region. All these variations affects the microwave propagation in the area, especially the rise in the values of k-factor above the global standard value of 1.333. The result of the k-factor (Table 4.8) show a monthly variation from 1.370 – 1.695, indicating that signal distortion is possible in the study area since the k-factor value is > 1.333. The effect of this result (large k-factor value) is that it will lead to major propagation condition known as super- refraction which mostly affects radio waves and then lead to signal interference over Sokoto area.
Read More

DETERMINATION OF NOISE POLLUTION BASE FROM WELDING AND FABRICATION WORKSHOP IN MAKURDI METROPOLIS

Determination of noise pollution base line of welding and fabrication workshop was carried out at some designated welding and fabrication workshops. These measurements was carried out in 10 different locations using the digital sound level meter of model 40773L. The sound pressure Level (SPL) was measured for every 2 minutes for 2hrs (120mins) and the equivalent noise level (Leq), Percentile (L10, L90) and the Noise Pollution Level (LNP) was also calculated. Fast Fourier Transformation was used to interpulate between minutes to give value in seconds and transformed measured values of time to frequency domain. Graphs were also plotted for noise against time and for power against the transformed measured values which are in frequency domain. The result of the research show that the equivalent continuous noise level in the selected site are SITE A: 94.74Db, SITE B: 89.82dB, SITE C: 92.90dB, SITE D: 90.03dB, SITE E: 87.10dB, SITE F: 87.86dB, SITE G: 91.33dB, SITE H: 92.86dB, SITE I: 89.24dB, and SITE J: 89.02dB, showing that some sites are noisier than others and the sum of the average values of noise data in welding and fabrication workshop in makurdi metropolis is 90.50dB Which is above the FEPA recommended values (90dBA) for 8hrs exposure time, which result to the possible health hazard of the noise level highlighted which include Annoyance, Cardiovascular disturbance, impalement of task performance and induced hearing loss.
Read More

DESIGN AND CONSTRUCTION OF AN OVER AND UNDER VOLTAGE PROTECTION CIRCUIT DEVICE [180-240V]

This project design and construction of over and under voltage protection circuit device (180V – 240V) is aimed at designing and construction of a device that can operate within a specified voltage range thereby helping to prevent the risk of voltage surge and burnouts. The device consists of a power supply unit which supplies power to all components within the circuit, two comparator units for detecting various levels of supply voltage (comparator unit 1 helps in monitoring the limit of the supply voltage i.e. 240V while comparator unit two helps in monitoring the lower limit of the supply voltage i.e. 180V), a transistor operating as a switch to trigger the final unit which is the relay (depending on the voltage level) that is directly connected to the load (e.g. refrigerator).   
Read More

DESIGN AND CONSTRUCTION OF AN ELECTRONIC VOTING MACHINE

This project was designed around microcontroller PIC16F876A. This microcontroller accepts data from the input unit processes the data and print the result in the output unit of this project. The input unit was designed using push buttons and its associated circuitry while the output unit is designed around 16×2 Liquid Crystal Display (LCD). The input unit has five buttons, four of which were dedicated to a particular political party (APC, PDP, CAN and PDC) while the fifth one is for result. When any of the button is pressed (casting of voting), the microcontroller records its value and when the result command is given, it calculates the value of each party, prints their respective number of votes on the output unit and announce the party with the highest votes (party whose button was pressed more) as the winner. In case that two or more party has equal highest number of votes, the election is dimmed to be inconclusive; hence, to determine the true winner, a by-election should be conducted by continuing the voting process.
Read More